- Home
- ยป
- Products & Services
- »
- Load Cells
Load Cells
Digital Compression Load Cells
Capacity | 30 Ton |
Material | Alloy Steel |
Ingress Protection | IP68 |
Zero balance | +/- 1% FS |
Insulation resistance at 50V DC | >= 1000 M Ohm |
Compensated Temperature Range | -10 to +40 Deg C |
Cable Length | 1-20 m |
Features:
- Reliable
- Long Lasting
- Economical
Cast Iron Weights
Shape | Hexagonal |
Surface Treatment | Polished |
Usage/Application | Industrial |
Color | Black |
Material | Cast Iron |
Load Range | 20 kg to 1 Ton |
Application | Pipeline manhole cover |
Features:
- High strength
- Longer life
Single Point Load Cell
Product Brochure
Brand | Flintec |
Model | PC46 |
Capacity | 50 Kg- 250 Kg |
Material | Aluminum |
Ingress Protection | IP67 |
Application | Platform Scale |
Features | Hermetically Sealed |
Load Cell Certifications | ATEX, OIML, NTEP |
Output Sensitivity(FS) | 2.0 +/- 0.1 mV/V |
Combined Error | <= +/- 0.0200 |
Creep Error (30 minutes) | <= +/- 0.0166 |
Accuracy Class | OIML R60 C3 |
Temperature Effect on Zero | <= +/- 0.0187 |
Temperature Effect on Output | <= +/- 0.0100 |
Zero balance | +/- 5% FS |
Maximum Safe Overload | 150% FS |
Ultimate Safe Overload | 300% FS |
Recommended Excitation Voltage | 5 to 15V DC |
Maximum Excitation Voltage | 15V DC |
Input Resistance | 413 +/- 20 Ohm |
Output Resistance | 350 +/- 25 Ohm |
Insulation resistance at 50V DC | >= 5000 M Ohm |
Compensated Temperature Range | -10 to +40 Deg C |
Operating Temperatue Range | -35 to +65 Deg C |
Load Cell Intervals (nLC)/Divisions | 3000 |
Cable Length | 3 Meter |
We provide finest quality Single Point Load Cell with most premium standards and performance
Specifications:
- Packaging & Grading Machines
- Bench Scales
- Bottle filling machinery
- Bag filling equipment
- Environmentally Sealed by Potting
- Stainless Steel Construction
- Wide range of capacities
- High Accuracy
- OIML, NTEP, ATEX, FM Certified
Single Ended Shear Beam Load Cell
Product Brochure
Brand | Thames |
Model | T85 |
Type | Single Ended Shear Beam |
Capacity | 300 Kg- 10 Ton |
Material | Stainless Steel |
Ingress Protection | IP67 |
Application | Pallet Truck Scales |
Features | Hermetically sealed |
Load Cell Certifications | OIML, ATEX |
Output Sensitivity(FS) | 2.0 +/- 0.1 mV/V |
Combined Error | <= +/- 0.017 |
Creep Error (30 minutes) | <= +/- 0.016 |
Accuracy Class | OIML R60 C3 |
Temperature Effect on Zero | <= +/- 0.002 |
Temperature Effect on Output | <= +/- 0.0012 |
Zero balance | +/- 2.0% FS |
Maximum Safe Overload | 200% FS |
Ultimate Safe Overload | 300% FS |
Recommended Excitation Voltage | 5 to 15V DC |
Maximum Excitation Voltage | 15V DC |
Input Resistance | 400 +/- 20 Ohm |
Output Resistance | 350 +/- 3 Ohm |
Insulation resistance at 50V DC | >= 5000 M Ohm |
Compensated Temperature Range | -10 to +40 Deg C |
Operating Temperatue Range | -35 to +65 Deg C |
Load Cell Intervals (nLC)/Divisions | 3000 |
Cable Length | 12 Meter |
We provide premium quality Single Ended Shear Beam Load Cell with the most superior standards and performance
Application:
- Low Profile Floor Scales
- Tank, Hopper & Bag Weighing
- Force, Tension Measurement
- Industrial Automation
- Pallet Scale
Double Ended Shear Beam Load Cell
Product Brochure
Brand | ADI |
Model | 80210 |
Type | Double Ended Shear Beam |
Capacity | 10-100 Ton |
Material | Nickel Alloy Steel |
Ingress Protection | IP68 |
Application | Tank & Vessel Weighing |
Features | High Accuracy & Precision |
Load Cell Certifications | OIML |
Output Sensitivity(FS) | 3.0 +/- 0.08 mV/V |
Creep Error (30 minutes) | <= +/- 0.03 |
Accuracy Class | OIML R60 C3 |
Temperature Effect on Zero | <= +/- 0.0020 |
Temperature Effect on Output | <= +/- 0.0015 |
Zero balance | +/- 1.5% FS |
Maximum Safe Overload | 150% FS |
Ultimate Safe Overload | 300% FS |
Recommended Excitation Voltage | 10 to 12V DC |
Maximum Excitation Voltage | 15V DC |
Input Resistance | 770 +/- 20 Ohm |
Output Resistance | 700 +/- 7 Ohm |
Insulation resistance at 50V DC | >= 1000 M Ohm |
Compensated Temperature Range | -10 to +40 Deg C |
Operating Temperatue Range | -35 to +65 Deg C |
Load Cell Intervals (nLC)/Divisions | 3000 |
Cable Length | 20 Meter |
We deal in good quality Double Ended Shear Beam Load Cell with the most premium standards and performance
Features:
- Batching, Blending & Mixing Systems
- Excellent Performance for High Capacity Loading
- Excellent Combined Error & Repeatability
- Level & Inventory Monitoring
- Tank, Bin & Silo Weighing
S Type Loadcell
Product Brochure
Brand | Flintec |
Model | UXT |
Capacity | 50 Kg- 7500 Kg |
Material | Nickel Alloy Steel |
Ingress Protection | IP67 |
Application | Tensile Testing Machine |
Features | Hermetically Sealed, High Accuracy & Precision, Current Calibrated |
Load Cell Certifications | NTEP, OIML, ATEX |
Output Sensitivity(FS) | 2.0 +/- 0.1 mV/V |
Combined Error | <= +/- 0.0200 |
Creep Error (30 minutes) | <= +/- 0.0166 |
Accuracy Class | OIML R60 C3 |
Temperature Effect on Zero | <= +/- 0.0116 |
Temperature Effect on Output | <= +/- 0.0100 |
Zero balance | +/- 5% FS |
Maximum Safe Overload | 150% FS |
Ultimate Safe Overload | 300% FS |
Recommended Excitation Voltage | 5 to 15V DC |
Maximum Excitation Voltage | 15V DC |
Input Resistance | 400 +/- 50 Ohm |
Output Resistance | 350 +/- 2 Ohm |
Insulation resistance at 50V DC | >= 5000 M Ohm |
Compensated Temperature Range | -10 to +40 Deg C |
Operating Temperatue Range | -35 to +65 Deg C |
Load Cell Intervals (nLC)/Divisions | 3000 |
Cable Length | 6 Meter |
We provide finest quality S type loadcell with the best in class standards and performance available
Features:
- Designed for single or multiple load applications
- Integral Loading Bracket
- Truck Scale Conversions
- Tension & Compression measurements
- Level & Inventory Monitoring
- Tank, Bin & Hopper Weighing
Compression loadcell
Product Brochure
Brand | Flintec |
Model | RC3 |
Capacity | 7.5 Ton- 300 Ton |
Material | Nickel Alloy Steel |
Ingress Protection | IP68 |
Application | Silo & Tank Scale |
Features | Current Calibrated |
Load Cell Certifications | ATEX, NTEP, OIML |
Output Sensitivity(FS) | 2.0 +/-0.1 mV/V |
Combined Error | <= +/- 0.0200 |
Creep Error (30 minutes) | <= +/- 0.0166 |
Accuracy Class | OIML R60 C3 |
Temperature Effect on Zero | <= +/- 0.0093 |
Temperature Effect on Output | <= +/- 0.0100 |
Zero balance | +/- 5% FS |
Maximum Safe Overload | 200% FS |
Ultimate Safe Overload | 300% FS |
Recommended Excitation Voltage | 5 to 15V DC |
Maximum Excitation Voltage | 15V DC |
Input Resistance | 1150 +/- 50 Ohm |
Output Resistance | 1000 +/- 2 Ohm |
Insulation resistance at 50V DC | >= 5000 M Ohm |
Compensated Temperature Range | -10 to +40 Deg C |
Operating Temperature Range | -35 to +65 Deg C |
Load Cell Intervals (nLC)/Divisions | 3000 |
We provide premium quality Compression loadcell with the top class standards and performance
Features:
- Simple Installation
- ATEX and High Temperature versions available
- Stainless Steel Load Sensor
- Self-Centering column design with anti-rotation pin
- Environmental protection IP68/IP69K
- Tank Weighing
Analog Load Cells
Material | Stainless Steel |
Safe over load | 200 % |
Ultimate over load | 300 % |
Key Features:
- It is a perfect fit for use in harsh industrial environments
- Environmental Protection IP68
- Self restoring design
- High input resistance
- Calibration in mV/V/Ω
- Safe over load of 200% & Ultimate over load of 300%
- Constructed with stainless steel 17-4 PH (1.4548)
Approvals:
- OIML approval
- NTEP approval to 6000 intervals, Class III (for 7.5 to 75 t)
- ATEX hazardous area approval for Zone0, 1, 2, 20, 21 and 22
- FM hazardous area approval
Load Cell
Type | Analog |
Material | Stainless Steel |
Safe over load | 200 % |
Ultimate over load | 300 % |
Key Features:
- It is a perfect fit for use in harsh industrial environments
- Environmental Protection IP68
- Self restoring design
- High input resistance
- Calibration in mV/V/Ω
- Safe over load of 200% Ultimate over load of 300%
- Constructed with stainless steel 17-4 PH (1.4548)
Approvals:
- OIML approval
- NTEP approval to 6000 intervals, Class III (for 7.5 to 75 t)
- ATEX hazardous area approval for Zone0, 1, 2, 20, 21 and 22
- FM hazardous area approval
Button Load Cell
Product Brochure
Brand | ADI |
Model | 90610-M |
Capacity | 200 - 3000 Kg |
Material | Alloy Steel |
Ingress Protection | IP65 |
Application | Compression Testing |
Features | High Accuracy & Precision |
Load Cell Certifications | OIML |
Output Sensitivity(FS) | 2.0 +/- 0.2 mV/V |
Creep Error (30 minutes) | +/- 0.03%FS |
Accuracy Class | OIML R60 C3 |
Temperature Effect on Zero | +/- 0.005%FS/DegC |
Temperature Effect on Output | +/- 0.005%FS/DegC |
Zero balance | +/- 1% FS |
Maximum Safe Overload | 150% FS |
Ultimate Safe Overload | 250% FS |
Recommended Excitation Voltage | 10 to 12V DC |
Maximum Excitation Voltage | 15V DC |
Input Resistance | 390 +/- 10 Ohm |
Output Resistance | 350 +/- 3 Ohm |
Insulation resistance at 50V DC | >= 1000 M Ohm |
Compensated Temperature Range | -10 to +40 Deg C |
Operating Temperatue Range | -35 to +65 Deg C |
Load Cell Intervals (nLC)/Divisions | 3000 |
Cable Length | 1 meter |
We supply supreme quality Button Load Cell with the most superior standards and performance available.
Specifications:
- Silo, Tank, Vessel Weighing
- Low Profile, extremely compact loading assembly
- Allows Vessel expansion & contraction
- Integral Jacking Facility
- 1000 division accuracy
- Environmental Protection IP68/ IP69K
- Allowance for Angular Mis-alignment